Optimal scan time of 18F-fluorocholine (FCH) PET/CT for localization of hyperfunctioning parathyroid glands is poorly documented. We report a small series of 9 histologically proven hyperfunctioning parathyroid gland with heterogeneous temporal uptake profile. Thirty-minute dynamic acquisition starting just after 18F-fluorocholine administration and delayed acquisition were recorded. Three different uptake patterns are seen (early washout, stable uptake, late increase) indicating the importance of an early (5–10 minutes) acquisition. A late acquisition (60 minutes) could be useful when the early acquisition is negative. No correlations were noted between uptake profile and histological or genetic results.
Fichier non déposé

Dates et versions

hal-01822373 , version 1 (25-06-2018)

Identifiants

Citer

David Morland, Capucine Richard, François Godard, Sophie Deguelte, Brigitte Delemer. Temporal uptake patterns of 18F-fluorocholine among hyperfunctioning parathyroid glands. Clinical Nuclear Medicine, 2018, 43 (7), pp.504-505. ⟨10.1097/RLU.0000000000002132⟩. ⟨hal-01822373⟩